Ecowitt Gw1000 Api, included in the purchase price of hardware). Many Fine Offset console models support this "Customized" Ecowitt upload protocol. 5 removed this data structure. You can still work with GW3000 via GW1000 protocol, but some of the new sensors (like new laser distance sensor) will only be supported via new API. Das Abfrageintervall (Polling) z. It costs about $20 on AliExpress. I can confirm that the GW1000 does send Dew Point via the local API from having read the API documentation and worked with the API myself. The GW1000 has another way of providing data which is using its built in API. In addition to Ecowitt. In CMD_READ_SENSOR_ID_NEW, a single battery data parsing is done for each sensor. I have just received the Ecowitt WittBoy machine and would like to use the Ecowitt API, so very willing to test and help out. 5OFFSET calibration data = 0x30 The Ecowitt Gateway driver (formerly the GW1000 driver) is a WeeWX driver that supports devices compatible with the Ecowitt LAN/Wi-Fi Gateway API. I've GW2000 Versione italiana della brochure Home Assistant - Ecowitt Official Integration Ecowitt Official Integration API from ecowitt official cloud server 2/22/2023 HTTP API interface Protocol for LAN (Generic) 01/14/2026 Basically, you need a gateway made by Misolie; the Misol GW1000 is exactly identical to the ecowitt GW1000. WH2650, WH2600Pro WiFi, Steinberg sbs-ws-600, Waldberg Halley . 5OFFSET calibration data = 0x2F, // writeback PM2. 支持: = 0x27, // read current data,reply data size is 2bytes. net API release Ecowitt is ready to release the API in this final phase, and wanting to provide a satisfactory service for all needs, asks the users' opinion on the use they would like to make and which characteristics it should satisfy for those who want to assist them in this process, send an email to my ecowitt address, each report will be forwarded directly to the Fine Offset As a result, when an Ecowitt string is received by the GW1000, it is forwarded in parallel and unprocessed to these defined forwards. The Ecowitt Gateway driver (formerly the GW1000 driver) is a WeeWX driver that supports devices compatible with the Ecowitt LAN/Wi-Fi Gateway API. The weather station supports doing a post to a custom URL, so I created a listener with If you don't want to use the ecowitt_http_gateway, you can use the Interceptor driver to sniff data of your GW1000, or you can use the API broadcast methos driver that uses the same protocol used by VSView, WeeWx must stay on the same network of the GW1000. Thanks to @sburke781 for his work with re-releasing the EcoWitt gateway. No other Fine Offset console supports this API (pull mehtod). I have setup a new PWS (Ambient Weather WS-2000). net site with no problems. 0 released (for HP2560 and HP2550 last hardware revision consoles released. Für die Ecowitt GW1000, WH2650, GW1100, GW2000 und WN19x0 Konsolen (auch Gateways, Hubs genannt) gibt es den weewx Ecowitt Gateway Treiber (alter Name: GW1000 API Treiber), der die Daten direkt vom Konsolen- API ausliest. (14-Nov-2022) updated chapter 14 - Ecowitt Gateway (GW1000) API (15-Nov-2022) WiFi firmware EasyWeatherPro V5. Und ich habe Ecowitt angeschrieben, nach einem Angebot für den Blitz/Donner WH57 Sensor, sowie der non public API zum DP1500 / G1000. Deploy Docker + weewx-interceptor, plus Duplicati backups, add MQTT. This is a push method. Ecowitt says it is. I had hoped to get Cumulus MX ready to use this once it was released, it looks like I'll have to play catch-up. Ecowitt. Even if that was a small subscription service to pay for their server load (vs. There are other things you can do with Customized server settings besides these listed below. 1. The Ecowitt Gateway driver utilises the Ecowitt LAN/Wi-Fi Gateway API thus using a pull methodology for obtaining data from the gateway device rather than the push methodology used by other drivers. G1ZFO Ecowitt HP2551A + WH65 Tri-Wing (Wunderground: IGUILDFO67) Ecowitt GW1000 (Wunderground: IGUILDFO68) Ecowitt GW1000 (Mk2) test environment driving CumulusMX on a RPi 3b Ecowitt GW2000 (Test) Ecowitt WS90 Wittboy - Test Ecowitt WH51 (x6) Soil Moisture Sensor Ecowitt WH41 PM2. Note that the Ecowitt Gateway Driver will communicate directly with the GW1000 and GW2000 wifi bridge devices, and that solution is typically easier to configure than using the weewx-interceptor Worked straight away with the GW1000 + a range of sensors and its great that we can still upload to the ecowitt server as well as HA. Collect data from the ecowitt GW1000 wifi bridge This guide shows how to collect data from the GW1000 wifi bridge using the weewx-interceptor driver. Ecowitt API Server The world pioneer in weather instruments innovation Go to Member center Ecowitt provides professional weather products to people around the world. 6. Mal sehen ob/wie Ecowitt antwortet This looks like exactly what is required to support the Ecowitt GW1000 weather station. A WeeWX driver based on the Ecowitt LAN/Wi-Fi Gateway API - weewx-contrib/weewx-gw1000 If you don't want to use the ecowitt_http_gateway, you can use the Interceptor driver to sniff data of your GW1000, or you can use the API broadcast methos driver that uses the same protocol used by VSView, WeeWx must stay on the same network of the GW1000. Contribute to bmrzycki/gw1000-http development by creating an account on GitHub. Hi Gang, I'm relatively quiet on this board, but I did feel compelled to share (with anyone interested) that the value of my Ecowitt System (GW1000 gateway + a whack of sensors. Hi, I bought one Ecowitt WH51 Soil Moisture Sensor and the Gateway GW1000 Wi-Fi. Ecowitt GW1000 HTTP REST API front-end server. Ecowitt provides professional weather products to people around the world. for the time being firmware 1. The frequents reboot of the GW1000/WH2650 devices introduced with 1. The best way to support 3rd party software is by adding the GW1000 and then adding the 3rd party software to some other device. B. Don't buy Ecowitt Gw1000 in Canada before reading our rankings | bestproductscanada. GW1000 WiFi gateway 3 posts • Page 1 of 1 OldAlaskaGuy Posts: 59 Joined: Wed May 07, 2025 11:57 pm Weather Station: Ambient WS2902 + Ecowitt GW3000 Operating System: Windows 11 24H2 Location: Nikiski, Alaska A better solution would be for Ecowitt to provide an open API to interrogate/export data rather than just upload it. 5 AQM Sensor Ecowitt WH31 (x8) Thermo/Hygro Sensor supports new JSON API for Ecowitt GW3000 and defined GW3000 as a separate weather station. I’m totally done with Netatmo at this point and I am more than happy to show you my new setup at my home. Im having some trouble with the data conversions in WeeWx, and I'm not exactly sure what's happening. The function of the API is for the API driver to hit the GW1000 via its IP address and speak directly to the GW1000 and basically say to the GW1000, "Hey, send me data" and the GW1000 takes note of where the request came from and it responds. I have a Metoebridge setup with the Davis vantage station and with the ecowitt GW1000. With strong technology and factory backup, ecowitt will be your perfect choice! Check our store for more weather products. Misol soil moisture and temperature/humidity sensors are also identical to the equivalents sold as ecowitt sensors, and cost between $5-10. Now the problem is to have in node red the values values detected by the Ecowitt api . 4 for GW2000 are rather stable. It was started back in July of 2019 but has seen quite a bit of change over time. While the consoles with the Ecowitt Gateway API (GW1x00, GW2000, WN19x0) have a compensation switch for a WH24 in their device settings, the HP25x0 and HP350x consoles don't. The driver also supports the Ambient Local method AND Ecowitt protocol (such as for the GW1xxx devices). com Crossposted under Ecowitt GW1000 Gateway (moved here for visibility). The three main methods are: Ambient API: Allows you to connect to the Ambient Weather API using an API Key you obtain You can determine WHEN a query is made (pull - as opposed to the custom server push), have no additional configuration required and the queries are much simpler than with the GW1000-API. I managed to get the custom interceptor. conf eingetragen. 2. alle 10 Sekunden wird in der weewx. I have also setup the device driver (snell) for Hubitat to retrieve the data from AmbientWeather just looking for the folks that know the HE "back end" stuff and Ecowitt's track record (as a development team) and the simplicity of the API to weigh in on the likelihood of the GW2000 API being the same as the GW1000 which they're familiar with. Connect an Ecowitt WS2910 to WeeWX via the GW2000 gateway: Ecowitt WS2910 → GW2000 gateway → dockerized WeeWX. The API was originally designed for the GW1000 because it was the only console wothout a display and there needed to be a way to show live data on the mobile app to see the status of the sensors. So, I developed ecowitt2mqtt, a small web server that receives data from the GW1000 and sends it to an MQTT broker. The Ecowitt integration works by first creating a callback endpoint on your Home Assistant instance and then adding this configuration to the Ecowitt console so that it starts sending data. ) took a massive leap forward in usefulness within the past few weeks. I didn't think much of this issue at the time because I thought it was just a developer programming choice for whatever reason. Whether the greater technical possibilities (such as multiple parallel threads for sending to the various services or querying via GW1000 API) are already being used, I don't know for sure. g. . "free" forever i. This creates a local API for devices that would otherwise strictly communicate via a cloud API. other recipes you may find here: Ecowitt GW1000 HTTP REST API front-end server. = 0x28,// read Soilmoisture Sensor calibration parameters = 0x29, // write back Soilmoisture Sensor calibration parameters = 0x2C, // read multi channel sensor offset value = 0x2D, // write back multi channel sensor OFFSET value = 0x2E, // read PM2. Support for WeeWx using this API method will come. Can you change a Station ID Odd one I've just taken delivery of my new Ecowitt kit (finally) I am going to be running a personal webserver using a Raspberry Pi and WeeWx with an RTL-SDR to grab the data. I guess this is how CMX works for data but cant find anything on how to access it localy. 9 - 1. Feb 3, 2023 · For this purpose, the device offers a local API. However, in addition it offers a local API for pulling data directly rather than from the cloud. Ecowitt Official Integration API from ecowitt official cloud server 2/22/2023 HTTP API interface Protocol for LAN (Generic) 01/14/2026 TCP API interface Protocol (Generic) 01/09/2026 Data support over the TCP protocol is no longer maintained, and newly introduced sensors will not be supported in future updates. 2 for GW1000/WH2650, 2. I’ll start with a WS69 (all-in-one) sensor and the Gateway GW1100. 7. 4 for GW1100 and 2. typedef union // 1 Low Batt, 0 Normal { unsigned char batt; The ECOWITT GW1000 WiFi Gateway is a central component of the ECOWITT Smart Sensor Series, designed to collect data from various wireless weather sensors and make it accessible via a mobile application and cloud services. Combined with WeeWX we will publish our data to some online weather networks/services. Note that the Ecowitt Gateway Driver will communicate directly with the GW1000 and GW2000 wifi bridge devices, and that solution is typically easier to configure than using the weewx-interceptor Der Blog erklärt detailliert, wie man den Ecowitt WS90 mit Shelly-Systemen per GW1000-Hub und MQTT/HTTP-Schnittstelle verbindet, und gibt praktische Tipps für eine stabile Integration und Montage. I have it sending data to WeatherUnderground as well as the AmbientWeather. Looking at using a couple of Ecowitt sensors but wouls like to access GW1000 local to retrieve data. net API release I have not seen anything about alpha/beta testing this? I raised a concern with Ecowitt about the whole approach of this API and a possible problem and heard nothing back confirming my thoughts one way or another. The API documentation requires that you send commands using specifically formatted TCP packets to the device. 1 has also diminished with 1. Unlike, for example, the Davis WeatherLink Live, Ecowitt does not document an option to retrieve the data via an HTTP request with a neat JSON response. This is a set of drivers originally designed to support polling the Ambient Weather API. I do have a GW1000 as well but using that means I cannot get the internal temperature I want from the WH32B as the GW1000 will be installed somewhere much cooler than the main house. py installed, and is currently listening to my GW1000 in Ecowitt mode. Meteobridge can handle a broad range of weather stations from consumer entry level up to prosumer/professional stations from Davis Instruments, PeetBros or Rainwise. Finally I came across Ecowitt's GW1000 device which is capable of connecting to your Wifi and submitting the data to various weather data collection services (Ecowitt's own, wunderground etc) or Easily compare & choose from the 10 best Ecowitt Gw1000 for you. Just one question does anyone else use the soil moisture wh51? The Ecowitt GW1000 is a very powerful option to ether Ambient or Ecowitt station (or other Fine Offset). Recently, @jwoodard80 tipped me off to the Ecowitt GW1000, a small device that can read RF signals from a variety of devices (such as Ambient Weather weather stations). I have discovered that the Ecowitt GW1000 works 100% with the Ambient Weather WS2000 /WS2902 Array. This is primarily because it is the only console to support a local network API. This API is exclusive to the GW1000. Is there a step-by-step for someone with limited technical knowledge on how to get the lightning detector data to display on my meteotemplate dashboard (Blocks are installed, but I suspect the API is not setup, hoping this makes sense?) Hi Guy, in your setup and if the api-php files are in /public_html/Data_Comparison/api/ (as i assume) then you cannot derive your dayfile location from __DIR__ as Ecowitt2mqtt: Send data from an Ecowitt device to MQTT Share your Projects! Recently, @jwoodard80 tipped me off to the Ecowitt GW1000, a small device that can read RF signals from a variety of devices (such as Ambient Weather weather stations). e. ecowitt API available now HI, to use the Ecowtt API in 2 different Android applications, do I have to create 2 different "API Key" and 2 different "Application Key" (one for each application), or a single "API Key" and 2 different "Application Key"? I have not honestly understood from Ecowtt Api Docs, specifying that in an application I perfectly receive the data, in the other the Weather Jan 9, 2026 · #if 0 // GW1000 Firmware V1. ) or a HP2551 (clone) console. If you don't want to use the ecowitt_http_gateway, you can use the Interceptor driver to sniff data of your GW1000, or you can use the API broadcast methos driver that uses the same protocol used by VSView, WeeWx must stay on the same network of the GW1000. As this has become a frequently reported / posted issue here in the forum, below the instructions and prerequisites for a successful connection of a GW1000 or other consoles with GW1000 functionality (e. qyr9m, phqi7, 8oz80, o9sv, 5vdvs, evyq, qg4vu, v8xon, us0wu, 35km9,